热线电话:+86 512 6799 8818

在线咨询

TOP

*姓名

*电话

邮箱

咨询内容

*验证码

联系销售


Sales Image

联系销售助理


Sales Assistant Image

联系PM


PM Image
GentleGen's Practical Handbook for High-Throughput Antibody Screening — Supernatant Expression Purification Q&A
Release time:2026-11-23
Share:

How much is the expression level of antibody supernatant?

Based on our extensive experience in high-throughput expression: most conventional IgG antibody supernatants can reach 200 μg/ml; The expression level of VHH nanoantibodies is generally superior to that of IgG, and higher supernatant concentrations can usually be achieved under the same expression system.

 

However, antibody concentrations in the supernatant fluctuate due to factors such as antibody sequence and expression system (HEK293/CHO). If higher concentrations or purified antibodies are required, we also offer purification services.

 

How is antibody supernatant quality controlled?

  • Sample traceability: The original well coordinates of the 96-well plate are fully bound, with each sample corresponding to clear plate numbers and row-column position information;

 

  • Electrophoresis sampling: Sample supernatant at 10% of the well positions by plate, using reduced SDS-PAGE electrophoresis for preliminary qualitative quality control, intuitively determining whether the target strip exists or shows obvious degradation; Full-board quality inspection can also be chosen;

 

  • Plasmid Quality Control: When delivering matching plasmids, the original Sanger sequencing spectrum is provided simultaneously to confirm sequence consistency with the design sequence, eliminating plasmid mutations and frameshift issues.
     

 

What expression vectors can be used?

Our proprietary standardized carrier library is available for priority selection.

 

载体

 

If there is no matching carrier in the database, two solutions are supported:

 

  • You provide the carrier yourself, and we can keep samples for your future use;

 

  • We carry out carrier renovations. After renovation, the carriers are stored in the internal warehouse, and only a one-time renovation fee is charged. Subsequent reuse of the same carrier will not be charged again.

 

Will high-throughput synthesis + expression confuse samples?

GentleGen's entire high-throughput synthesis, translation, culture, and expression workflow is fully automated at most nodes, reducing the risk of human mismatch caused by manual pipetting and dispensing.

 

To date, we have delivered 700,000+ well-situated high-throughput antibody projects, with no issues of sample confusion or cross-pore in our delivery history.

 

After 1 ml of expression + purification, what is the antibody protein buffer?

Different labels require different elution and storage buffer systems: Fc labeled antibodies use glycine-Tris buffer; His labeled antibody is a buffer system containing imidazole.

 

Currently, the supernatant expression purification in the 1ml system does not support substitution with PBS buffer.

 

What is the purity of 1ml antibody expression purification?

This high-throughput 1ml system purification service does not issue purity test reports or commit to purity indicators.

 

Different antibody molecules differ greatly in hydrophobicity, aggregation tendency, and heteroprotein binding characteristics, resulting in significant fluctuations in final purity. Combined with internal parallel test data: the purification of most conventional antibodies is between 80%~90%.

 

Can well positions be selectively purified for purification?

This product line is a high-throughput batch purification process, with equipment and workflows designed for automated processing of entire boards. Currently, it only supports simultaneous purification of all wells on the entire board; single holes or selected pores are not supported for individual purification.

 

Full-process automation: making AI high-throughput screening routine in laboratories

GentleGen leverages its independently developed GentSyn-Exp3.0G-Lab fully automated production line to create a one-stop, high-throughput technology platform covering gene design, synthesis, validation, protein expression, and antibody affinity characterization. Traditional R&D models rely heavily on manual validation, but GentleGen has redefined the efficiency and cost of wet experiments through automation.

 

  • High-throughput screening: High-throughput expression screening greatly reduces the detection cost of individual samples—IgG monoclonal antibody at 48.9 USD/clones, VHH nanobody at 28.9 USD/clones. Each antibody comes with 800 μl of antibody supernatant that can be directly used for functional validation—eliminating purification steps and skipping intermediate steps, providing a one-stop direct downstream test from gene to antibody.

 

1111-02

 

  • Full-chain coverage: gene synthesis and vector construction, transient transfection of mammalian cells and antibody supernatant expression, and high-throughput affinity characterization of Octet® RH96 BLI. Relying on the G-Lab automation platform, the entire process is connected, unified experimental standards, ensuring stable and comparable data within the same batch, and adapting to the feedback needs of AIDD model iterations. 

 

For more details about related services, please send an email to marketing@gentlegen.com.

Pre-sales consulting

Pre-sales consulting

A more reliable solution for your needs.
Download

Download

Welcome to our product library.
Sales network

Sales network

Complete sales and service network to ensure product quality.
Event Promotions

Event Promotions

Add to cart now and enjoy this shopping extravaganza!